Do not store or use gasoline or other flammable vapors and liquids in
the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your
building.
Immediately call your gas supplier from a neighbor’s phone. Follow
the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer,
service agency or the gas supplier.
WARNING: If the information in these instructions are not followed
exactly, a fire or explosion may result causing property damage,
personal injury or loss of life.
Owner’s Operation and Installation Manual for the
RHFE-750ETRA
Direct Vent Fireplace
INSTALLER: Leave
this manual with the
appliance.
CONSUMER: Retain
this manual for future
reference.
Table of Contents ........... 2
Safety Information .......... 2
Operating Instructions .... 6
Care and Maintenance ... 11
Fault Codes .................... 14
Installation Instructions .. 15
Consumer Support ......... 38
Vue de la page 0
1 2 3 4 5 6 ... 39 40

Résumé du contenu

Page 1 - RHFE-750ETRA

— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU SMELL GAS

Page 2 - Consumer Safety Information

10 Rinnai Corporation RHFE-750ETRA Timers Programming the clock and timers The clock must be set before the t

Page 3 - CAUTION

Rinnai Corporation RHFE-750ETRA 11 Care and Maintenance Filters This app

Page 4 - Specifications

12 Rinnai Corporation RHFE-750ETRA WARNING Do not clean glass when hot. Do not clean glass with abrasive cleaners. Care an

Page 5

Rinnai Corporation RHFE-750ETRA 13 Troubleshooting No display on remo

Page 6 - Operating Instructions

14 Rinnai Corporation RHFE-750ETRA Fault Codes If there is a malfunction the appliance may shut down as a safety

Page 7

Rinnai Corporation RHFE-750ETRA 15 Installation Instructions General Instructions

Page 8

16 Rinnai Corporation RHFE-750ETRA Flue Terminal Clearances INSIDECORNER D E TAI LFIXEDCLOSEDOPERABLEFIXEDCLOS

Page 9

Rinnai Corporation RHFE-750ETRA 17 Ref Description Canadian Installations US Installation

Page 10 -

18 Rinnai Corporation RHFE-750ETRA Do not vent the exhaust into ‘natural draft’ flue pipes or a chimney flue. The enclosure must be

Page 11

Rinnai Corporation RHFE-750ETRA 19 Correct FloorLevel InstallationParticle Board, MDF, Ply

Page 12 - WARNING

2 Rinnai Corporation RHFE-750ETRA Consumer Safety Information Safety Definitions ... 2 Safety Be

Page 13

20 Rinnai Corporation RHFE-750ETRA Flue Manifold Installation 1. Disassemble the Flue Manifold The flue consists of

Page 14

Rinnai Corporation RHFE-750ETRA 21 2. Assemble and Adjust the Sleeve Length Measure wall

Page 15 - Installation Instructions

22 Rinnai Corporation RHFE-750ETRA Venting 5. Lock the ties Pulling hard on the left and right hand ties, cl

Page 16

Rinnai Corporation RHFE-750ETRA 23 CONDENSATE COLLECTOR, 3CGDS HORIZONTAL TERMINATION, 3CG

Page 17

24 Rinnai Corporation RHFE-750ETRA Venting Vent Length Switch If using extended venting, move the dip switch in

Page 18 - 28.3 in (720 mm)

Rinnai Corporation RHFE-750ETRA 25 6. Unscrew the flue access panel held by two screws loc

Page 19

26 Rinnai Corporation RHFE-750ETRA Connections 9. Remove clamp L and slide the vertical pipe M down into the

Page 20

Rinnai Corporation RHFE-750ETRA 27 Final Assembly 1. Remove the two

Page 21

28 Rinnai Corporation RHFE-750ETRA Place the condensate tray on top of the lower panel on the left side under the condensate tube. P

Page 22

Rinnai Corporation RHFE-750ETRA 29 Air Guide Vanes To move the air flow more to the right o

Page 23

Rinnai Corporation RHFE-750ETRA 3 Safety Behavior and Practices Safet

Page 24

30 Rinnai Corporation RHFE-750ETRA Operating Instructions FOR YOUR SAFETY READ BEFORE OPERATING WARNING If y

Page 25

Rinnai Corporation RHFE-750ETRA 31 Wiring and Schematic Diagrams If any of

Page 26

32 Rinnai Corporation RHFE-750ETRA Parts List For replacement parts call Rinnai at 1-800-621-9419.

Page 27

Rinnai Corporation RHFE-750ETRA 33 Parts List

Page 28

34 Rinnai Corporation RHFE-750ETRA Parts List 1211301311201051041191321081061251071141101131121091119811574117

Page 29 - Front Panel

Rinnai Corporation RHFE-750ETRA 35 Parts List 1 1 10201 PANEL B

Page 30

36 Rinnai Corporation RHFE-750ETRA Parts List 48 2 10359F BURNER ASSEMBLY BRAY 250 Ø3.0 x 2 NG LEFT AND R

Page 31

Rinnai Corporation RHFE-750ETRA 37 Parts List ITEM QTY PART NO.

Page 32

38 Rinnai Corporation RHFE-750ETRA Consumer Support Warranty Information Limited Warranty

Page 33

Rinnai Corporation RHFE-750ETRA 39 Limited Warranty - continued What wi

Page 34

4 Rinnai Corporation RHFE-750ETRA Application Vented gas fireplace heater; Inbuilt only; for residential installation, commer-cial se

Page 35

15237 (Issue G) Manufactured by Rinnai New Zealand LTD 105 Pavilion Drive, Airport Oaks Mangerg, Manukau City New Zealand

Page 36

Rinnai Corporation RHFE-750ETRA 5 Features • Direct Vent: Intake

Page 37

6 Rinnai Corporation RHFE-750ETRA Operating Instructions Front Panel Description Part Number Flat Metal - Black

Page 38 - Consumer Support

Rinnai Corporation RHFE-750ETRA 7 • Use two 1.5V AAA batteries. • To replace batteries

Page 39

8 Rinnai Corporation RHFE-750ETRA Sequence of Operations The combustion fan will run for several seconds before igni

Page 40 - New Zealand

Rinnai Corporation RHFE-750ETRA 9 Adjusting the Temperature Pressing the UP and DOWN button