Rinnai Direct Vent Service Manual 37
RHFE-433RWTA
RHFE-558RWTA
Troubleshooting
Part Wire 433RWTA 558RWTA
OHS.
White - White
Below DC 1V, Below 2 Below DC 1V, Below 2
Blue - White (OHS1)
Blue - White (OHS2)
TF White - White (TF)
O.H. TH
White - White 0.87-482k, (<0.87k:Short, >482k:Open)
Temperature
32°F (0°C):113k, 68°F (20°C):39k,
86°F (30°C):24k, 104°F (40°C):15k
White - White
(Filter sign)
High
Flashes below 6.83k
Flashes below 6.40k
Low Flashes below 10.2k
White - White
(The TH operate)
High Operates below 4.97k
Low Operates below 7.29k
Room
Thermistor
Yellow - Yellow 1.82-707k, (<1.82k:Short, >707k:Open)
Temperature
32°F (0°C):113k, 68°F (20°C):39k,
86°F (30°C):24k, 104°F (40°
C):15k
FR Yellow - Yellow
Below 0.1ADuring Stop)
Combustion Fan
(In case of short
vent.)
White - Black Below ignition revolution +2Hz
Ignition
revolution
Initial LP: 65Hz, NG: 70Hz
Re-attempt LP: 65Hz, NG: 70Hz
Normal
revolution
High LP: 105Hz, NG: 102Hz LP: 120Hz, NG: 120Hz
Low LP: 70Hz, NG: 69Hz
Combustion Fan
(In case of long
vent.)
White - Black Below ignition revolution +2Hz
Ignition
revolution
Initial LP: 65Hz, NG: 70Hz
Re-attempt LP: 65Hz, NG: 70Hz
Normal
revolution
High LP: 105Hz, NG: 102Hz LP: 120Hz, NG: 120Hz
Low LP: 70Hz, NG: 69Hz
Ignitor Red - Blue 90-120V
SV Black-Yellow 80-100V, 1.5-2.5k
Modulating
Valve
Gray-Gray
DC6-16VLow-High), 80-90
Convection Fan Red - Black
56-75V
90-180
56-94V
90-180
Pressure Sensor Red - White DC3 - 7V
Transformer - Same as 431WTA Same as 556WTA