Rinnai RHFE-750ETR Manuel d'installation Page 22

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 24
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 21
Rinnai Australia 20 RHFE-750ETR & RHFE-752ETR Flue Installation Manual
CONNECTING HEATER EXHAUST & AIR SUPPLY
CONNECTING HEATER EXHAUST
1. Lubricate the O-Ring of the exhaust connection and fit the telescopic exhaust pipe of the heater.
Push the telescopic tube fully home so that the end of the exhaust connection and the collar of the
telescopic exhaust pipe are fully mated.
2. Attach the flue locking clamp provided with the heater over the telescopic exhaust pipe and the exhaust
connection of the flue transition. Ensure that the teeth of the flue locking clamp engage both
A the collar of
the telescopic exhaust pipe and
B the collar of the exhaust connection of the flue transition.
3. Close the clamp to secure both components together.
4. Adjustable the telescopic exhaust pipe to attain the desired position of the heater, DO
NOT extend beyond
the indicator groove.
5. Fix the telescopic exhaust in place with the exhaust lock. The clamp of the exhaust lock is attached to
the telescopic exhaust pipe whilst the finger tabs are secured around the collar of the fixed part of the exhaust.
CONNECTING COMBUSTION AIR HOSE
This section describes how to connect the exhaust pipe from the
Aspiration heater to the exhaust connection on flue transition
ASPDFK or ASPKIT03.
This joint MUST BE properly secured in accordance
with these instructions using the clips provided.
If this joint is not secured properly, products of
combustion could disperse into the room being heated
which may result in a dangerous condition.
The combustion air hose of the heater is attached to the
large diameter combustion air inlet.
Secure the combustion air hose to the
combustion air inlet with cable tie supplied with
the heater.
The air hose MUST BE properly secured in
accordance with these instructions for safe and
reliable operation of this heater.
The rubber cap (when supplied) is designed to fit
both the left and right hand combustion air inlet
and MUST cover the air inlet not in use.
Exaust Connection
ASPDFKASPKIT03
CAUTION
1
2 3
!
Telescopic Exhaust pipe
Exhaust connection
!
!
!
!
!
4 5
!
!
Maximum
limit of telescopic
extension
INCORRECT
over extension
of telescopic
extension
Collar
Collar
!
!
!
!
!
CAUTION