OVER HEAT SWITCH
When the heater gets too hot during operation (for example when the filters or air outlet louvers are blocked) this
device turns the gas and or electric heating element off automatically. Remove cause of overheat (clean filters) allow
heater to cool, then re-ignite.
FUSE
The electrical circuits are protected by a fuse. When the fuse blows, the heater will not operate at all. The fuse must
be replaced by an authorised person.
FLAME FAILURE DEVICE
This device automatically cuts off the gas supply to the heater in the event of a gas failure. To restore the gas supply
to the heater, turn it off, and then follow the ignition procedure.
OXYGEN DEPLETION SAFETY DEVICE
If the oxygen level in the room drops below a pre-set limit, this device cuts the gas supply to the heater. If the oxygen
depletion device operates, turn the heater off, ventilate the room, then follow the ignition procedure to re-light. Heater
will not re-light unit room is fully ventilated.
TILT SWITCH
If the heater is knocked over, the tilt switch will cut the gas supply and or the power to the electric heating element.
The fan keeps running. To restore the gas supply, stand the heater upright, turn it off then follow the ignition
procedure. The tilt switch may also operate if the heater is jolted or picked up whilst in operation.
POWER FAILURE
In the event of a power failure or power cut, the gas valves will automatically close. After the power is re-instated
the appliance must be operated manually.
CHILD LOCK
SAFETY DEVICES