17
Rinnai Corporation RHFE-201FA
Drilling Flue Hole
Check for water and gas pipes as well as electric
cables. Drill the flue hole using a 3 1/8 inch (80
mm) drill. The center of the hole must be located
exactly at the specified point.
A maximum of one elbow (FOT-158) may be
used to raise the flue manifold s position by 6 in
(154 mm) relative to the appliance. Rotate the
flue elbow 90°to a vertical position and attach
the FOT-158 so that it opens tow ard the
center of the appliance. If the FOT-158 is
used then do not use the tem plate. The
center of the w all opening w ill be 16 1/2 in
(418.5 mm) above the base of the appliance.
See diagram. For weatherboard walls, drill
through the center of the weatherboard from the
outside first and then through the plasterboard. A
template is provided.
Dimensions