Rinnai Corporation RHFE-201FA
Application For manufactured home (USA only) or mobile home or residential or
light commercial installation convertible for use with natural gas and
liquefied petroleum gases when provision is made for the simple
conversion from one gas to the other.
General Description Forced combustion, forced convection, flued gas furnace
Operation Push button electronic
Gas Connection 1/2 in female NPT
Gas Control Electronic
Burners Stainless steel Bunsen burner
Temperature Control Electronic thermostat
Ignition System Electronic spark ignition
Flue System The flue must be terminated to atmosphere with only flue
components listed with the appliance’s certification. Warranty will be
voided if non listed components are installed.
Humidifier Tray Capacity - 1.5 pints (700 cc)
Electrical Connection AC 120V, 60 Hz, 42 watts
Weight 39.4 lbs (17.9 kg)
Noise Level 27-34 dB
AFUE Rating Natural Gas: 80.6% Propane: 83%
Fan CFM output Low 48.3 - High 70.6
Specifications
Rinnai is continually updating and improving products. Therefore, specifications are subject to change
without prior notice.
The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous
operating conditions and was determined independently of any installed system.
Safety Features
Overheat: The appliance will automatically
shut down when the appliance exceeds a
predetermined temperature.
Flame Failure: The appliance will
automatically shut down if the burner flame is
extinguished.
Power Failure: The appliance will cut off the
gas if it loses electrical power.
Power Surge Fuse: A glass fuse on the PC
board protects against overcurrent. If the fuse
blows then all indicator lamps will be off.
Spark Detector: The appliance automatically
shuts down if there is an abnormal spark at
ignition.
Fusible Link: In case the overheat feature
prevents the temperature from rising then the
fusible link will break shutting off the appliance.
Appliance Specifications